The Liebherr HC 1570G carries climate class SN-T, built to perform fully in room air from 50°F to 109°F, but it is not rated for outdoor use. Keep it indoors and call us when it stops holding temperature.

Small kitchen with a stainless side-by-side refrigerator, a gas range and a microwave above it
Warm kitchens

Water at the hinge in a humid house

Most Hawaii homes have no central AC, so a fridge here often works in warm, damp air. Liebherr fits a heater behind the base plate to keep the lower hinge area dry. If beads of water show there or between the compartments, its output can be raised in setup mode; its default setting is medium. Try that first. If water still beads with the heater turned up, a door seal or the heater itself is next.

Indoor rooms only Hinge heater setting Seal checked next Windward to Kapolei
Kitchen with a stainless refrigerator set beside a window and wood cabinets

Lights and codes on a Liebherr fridge

Most Liebherr messages are quick owner tasks; one is a call to us. Generic cooling causes sit on the problem pages below.

F1 to F5

Liebherr treats any of these as an appliance fault. Write the exact number down before you call.

Air Filter LED

Pull the magnetic toe-kick grille, wash the filter by hand or in the dishwasher, then reset the LED.

Water-drop symbol

Time for a new water filter. It twists a quarter turn, with no need to shut the water off.

Flashing IceMaker LED

No water is reaching the ice maker. Check the supply valve and the line before anything else.

Door alarm beeping

It sounds after about 180 seconds open. A door that will not seal fully keeps it going.

Blinking tank light

On tank-fed models like the HC 1570G, refill with cold drinking water or re-seat the tank.

Two ice makers

Plumbed or tank-fed: two Liebherr ice makers

PointPlumbed, HCB 2092G familyTank-fed, such as HC 1570G
Water sourceHouse line through a Liebherr adapter on a metric R3/4 valvePull-out tank, cold drinking water only, no sugary drinks
Pressure40 to 90 psi with the filter, 22 to 87 psi withoutNone needed
OutputAbout 100 to 120 cubes a day at 0°F, about 150 with SuperFrostLimited by the tank
First iceUp to 24 hours; discard the first three batchesRefill when the LED blinks
Small cubesRaise fill one step only, to E 4Check the tank sits properly
CPSC records

Was my Liebherr in the 2011 door recall?

Only if it is one of the 30 inch bottom-freezer models named. On March 3, 2011, about 5,702 built-in units such as the C 1600, CI 1601 and CI 1700 were recalled because a door could detach, after ten reports and no injuries. Owners were told to look for a hinge pin that had popped up at the top or bottom. On November 16, 2011, about 8,000 freestanding CS 1601, CS 1640 and CS 1650 units sold February 2004 through July 2009 were added, after 16 more reports including two injuries.

Liebherr fridge settings

38°F
Recommended refrigerator setting
3 to 8 hrs
To settle after a fresh start
28°F
Lowest BioFresh-Plus setting on Monolith units
530 kWh
HC 1570G yearly use, against a federal 584

Sources: Liebherr HC 1570G and HCB 2092G use and care guides; Liebherr HC 2090G installation guide; CPSC 2011 recall notices; ENERGY STAR data

01

Ice maker

It is designed that way. Both freezer drawers must be fully shut or the ice maker will not run.
Only with Liebherr's own adapter, because the inlet valve has a metric R3/4 male thread. After that it takes a braided hose or a 1/4 inch OD copper line with a compression ring, plus a strainer in the valve connector. Old supply lines are not reused, and the shut-off valve must not sit behind the unit.
Liebherr warns that pressure outside its limits will likely cause ice maker trouble and can lead to a leak.
About 100 to 120 at 0°F, and it stops on its own when the bin is full.
From 36°F to 44°F in the fresh food section. Liebherr suggests 38°F.
02

Refrigerator

The BioFresh drawer holds just above 32°F, and its slider picks dry air for meat and dairy or humid air for produce. On Monolith refrigerators a third drawer can switch to BioFresh-Plus, down to 28°F, for fish.
Sabbath mode changes how the unit behaves, but it switches itself off after 120 hours. SuperCool also returns to normal after about six hours. If the cabinet is still warm after both end, the cause lies elsewhere; note any F code before you call.
No. Liebherr bans extension cords, two-prong adapters and power strips, and wants a grounded 15 or 20 amp, 110 to 120 VAC circuit, ideally a dedicated one.
Behind the bottom drawer, on the left inside wall of the cabinet, per CPSC.
ENERGY STAR lists the 19.5 cu ft built-in at 580 kWh a year, against a federal limit of 647.

Liebherr showing an F code?

Talk to a person
(808) 219-0537
Call Now →
Sun through Thu 6am-12am | Fri 6am-3:30pm
Call (808) 219-0537